Quick Start For the 1738-ADNX B-3
4. Click OK.
Now that you have created a new DeviceNet project, go on line
by clicking the Online icon on the toolbar.
5. A list of the available drivers in RSLinx appears. Drill down from
Ethernet into your ControlLogix project through the backplane
to your 1756-DNB in slot 3. Select channel A, as shown below.
6. Click OK to accept the path configuration.
7. Click OK to the prompt.
Your system may not be
configured as illustrated.
You must pick an Ethernet
driver that is configured
with the address of your
ControlLogix 1756-ENBT
bridge module.
The sticker on the front of
your 1756-ENBT module
identifies the IP address
configured for your
module.