Allen-Bradley 2-D Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Lecteurs de codes-barres Allen-Bradley 2-D. Allen-Bradley 2-D User manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Publication 1756-IN039D-EN-P - February 2003
Installation Instructions
ControlLogix™
Voltage/Current Input Module
Catalog Number 1756-IF16
Obtain a User Manual
This product also has a user manual (pub. no. 1756-6.5.9). To view it,
visit www.ab.com/manuals
or www.theautomationbookstore.com.
To purchase a manual, you can:
· contact your distributor or Rockwell Automation representative
· visit www.theautomationbookstore.com
and place an order
· call 800.963.9548 (USA/Canada) or 001.320.725.1574 (outside
USA/Canada)
To: See page:
Obtain a User Manual 1
Identify the Module Components 6
Note the Power Requirements 6
Install the Module 7
Key the Module and Removable Terminal Block/Interface Module 8
Wire the Module 12
Assemble the Removable Terminal Block and the Housing 16
Install the Removable Terminal Block onto the Module 16
Check the Indicators 17
Remove the Removable Terminal Block from the Module 18
Remove the Module 18
See Specifications 19
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Voltage/Current Input Module

Publication 1756-IN039D-EN-P - February 2003Installation InstructionsControlLogix™Voltage/Current Input ModuleCatalog Number 1756-IF16Obtain a User Ma

Page 2

10 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003If you cannot ground at the field device, follow these st

Page 3 - Environment and Enclosure

ControlLogix™ Voltage/Current Input Module 11Publication 1756-IN039D-EN-P - February 20032. Connect the insulated wires to:· the RTB (as shown belo

Page 4 - European Zone 2 Use

12 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003Wire the ModuleYou can only connect wiring to your module

Page 5 - IMPORTANT

ControlLogix™ Voltage/Current Input Module 13Publication 1756-IN039D-EN-P - February 200340913-M123456789101112131415161718192021222324252627282930

Page 6 - Note the Power Requirements

14 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 200340914-M12345678910111213141516171819202122232425262728293

Page 7 - Install the Module

ControlLogix™ Voltage/Current Input Module 15Publication 1756-IN039D-EN-P - February 2003After completing field-side wiring, secure the wires in th

Page 8 - Wedge-shaped tab

16 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003Assemble the Removable Terminal Block and the HousingInst

Page 9

ControlLogix™ Voltage/Current Input Module 17Publication 1756-IN039D-EN-P - February 2003Check the IndicatorsThe indicators show CAL status (green)

Page 10

18 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003Remove the Removable Terminal Block from the ModuleIf you

Page 11

ControlLogix™ Voltage/Current Input Module 19Publication 1756-IN039D-EN-P - February 20031756-IF16 Specifications Number of Inputs16 single ended

Page 12 - Wire the Module

2 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003ControlLogix is a trademark of Rockwell Automation, Inc.Im

Page 13

20 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003Module Scan Time for All Channels (Sample Rate Module Fil

Page 14 - Publication

ControlLogix™ Voltage/Current Input Module 21Publication 1756-IN039D-EN-P - February 2003Surge Transient ImmunityIEC 61000-4-5:+2kV line-earth (CM)

Page 15

22 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003The following information applies when operating this equ

Page 16 - 20853–M 20854–M

ControlLogix™ Voltage/Current Input Module 23Publication 1756-IN039D-EN-P - February 2003Notes:

Page 17 - Check the Indicators

Publication 1756-IN039D-EN-P - February 2003 PN 957726-55Supersedes Publication 1756-IN039C-EN-P - October 2000 Copyright © 2003 Rockwell Automation,

Page 18 - Remove the Module

ControlLogix™ Voltage/Current Input Module 3Publication 1756-IN039D-EN-P - February 2003Environment and Enclosure Prevent Electrostatic DischargeA

Page 19 - 1756-IF16 Specifications

4 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003Removal and Insertion Under PowerRepeated electrical arcin

Page 20

ControlLogix™ Voltage/Current Input Module 5Publication 1756-IN039D-EN-P - February 2003IMPORTANTWhen using this product, also consider the followi

Page 21

6 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003Identify the Module ComponentsYou received the following c

Page 22

ControlLogix™ Voltage/Current Input Module 7Publication 1756-IN039D-EN-P - February 2003Install the ModuleYou can install or remove the module whil

Page 23

8 ControlLogix™ Voltage/Current Input Module Publication 1756-IN039D-EN-P - February 2003Key the Module and Removable Terminal Block/Interface Modu

Page 24 - Rockwell Automation Support

ControlLogix™ Voltage/Current Input Module 9Publication 1756-IN039D-EN-P - February 2003Wire the Removable Terminal BlockWire the RTB with a 1/8 in

Commentaires sur ces manuels

Pas de commentaire