Chapter
5
Parameters and Programming
Overview of Parameters
This chapter describes both Display and Program parameters. Display parameters
are read only (they cannot be programmed), while Program parameters can be
changed to fit your motor control requirements. You must have a Program Keypad
Module to view or change parameters. The table below describes which parameters
apply to the Preset Speed and Analog Signal Follower models.
Some parameters pertain only to either the Analog Signal Follower or Preset Speed
model, not both.
Review the factory default settings. If your drive is equipped with a Program
Keypad Module, these parameters can be changed to meet your specific application
requirements. The table below provides a list of parameters that are frequently
changed.
Commonly Changed Parameters Table 5.A
Refer to the Programming Example on the next page for instructions.
Parameter Type Analog Signal Follower Model
Parameter Numbers
Preset Speed Model
Parameter Numbers
Display 1 – 19 1 – 15, 17 – 19
Program 30 – 62, 65 – 66, and 69 – 76, 78 – 84 30 – 59 and 61 – 73, 78 – 80
Indicates that parameter applies only to the Analog Signal Follower Model
Indicates that parameter applies only to the Preset Speed Model
Parameter Setting Default Setting
P30 - [Accel Time 1] Desired accel time. 10.0 sec
P31 - [Decel Time 1] Desired decel time. 10.0 sec
P33 - [Maximum Frequency] Maximum frequency required. 60 Hz
P34 - [Stop Mode Select] Desired stopping mode. 0
P35 - [Base Frequency] Motor rated nameplate frequency. 60 Hz
P36 - [Base Voltage] Motor rated nameplate voltage. 460V or 230V
P38 - [Boost Select] Desired V/F setting. 2
P42 - [Motor Overload Current] Motor nameplate Full Load Amps (FLA). 115%
P43 - [Current Limit] Desired maximum output current. 150%
P46 - [Input Mode] Desired control method. 0
P47 - [Output Configure] Desired output relay function. 0
P56 - [Reset Functions] Desired drive reset description. 0
P58 - [Internal Frequency] Desired internal frequency. 60.0 Hz
P59 - [Frequency Select] Desired frequency source. 0
P61 – P68 - [Preset Frequency 0-7] Desired preset frequencies. 0-7
P74 – P76 - [Analog Input] Desired analog input functionality. 0, 0.0, 100.0%