4.4.1. Power Cable Termination
Factory supplied motor power cables (MPC-30-25-3 for “C” series systems or
MPC-60-25-3 for “D” series systems) are designed to be terminated at the drive
during installation. A small portion of the cable jacket is removed which exposes
the shield braid. The exposed area must be clamped to the front of the drive chassis
(refer to Figure 4.2.2.2) using the clamp provided as discussed in chapter 3 of the
“Ultra 3000i Intelligent Positioning Drives Installation Manual” manual provided
with the drive.
The motor connection is made to the circular connector of the cable MPC-30-25-3
for “C” series systems or the MPC-60-25-3 for “D” series systems. Ensure the
connector keys are aligned and fully screw the connectors together.
Installation Manual: http://www.ab.com/manuals/gmc/2098-IN003C-EN-P-JUL01.pdf
Figure 4.2.2.2
Motor Power Cable Shield Termination
4.4.2. Position Sensor (Feedback) Connection
Connect the circular connector of the FSC-LA-25 cable to the motor feedback
connector. Connect the HDB15 connector of the cable to the CN2 connector on the
Ultra 3000i drive.
4.4.3. I/O Connections:
The Control Pendant, 24 VDC I/O power, and Motor Temperature Switch are
connected via the 44-pin connector CN1. The system is shipped with the connector
prewired.
AN-0130 13 of 22 Revision B